MI Cable Available for J, K, T and E Thermocouple Calibrations. Wire Diameters as Small as 1,5 mm. 304, 310, 316, 321 Stainless Steel Sheath Material or Inconel 600 Sheath Material. Bends Easily. High Quality Magnesium Oxide Insulation. Sold in units of 1 metre. Available in IEC Tolerance Class 1 or 2. More
OMEGACLAD™ wire (MI cable) is metal-sheathed cable containing thermocouple wires which are insulated from each other and from the sheath by highly compacted magnesium oxide (MgO). Metric size OMEGACLAD wire is available in 304, 310, 316, 321 Stainless Steel and Inconel 600 sheathing.
Available for J, K, T and E Thermocouple Calibrations. Wire Diameters as Small as 1,5 mm. Bends Easily. High Quality Magnesium Oxide Insulation. Sold in units of 1 metre. Available in IEC Tolerance Class 1 or 2.
The online configurator may not contain all available options. If you do not find what you are looking for, please contact us.
Complete informations can be found in the spec sheet (PDF), see the "Download" section.

Thermocouple Sensor / What is a Thermocouple?
A thermocouple is a sensor for measuring temperature. This sensor consists of two dissimilar metal wires, joined at one end, and connected to a thermocouple thermometer or other thermocouple-capable device at the other end. When properly configured, thermocouples can provide temperature measurements over wide range of temperatures.
Thermocouples are known for their versatility as temperature sensors therefore commonly used on a wide range of applications...

How is Temperature Measured?
Temperature can be measured via a diverse array of sensors. All of them infer temperature by sensing some change in a physical characteristic. Six types with which the engineer is likely to come into contact are: thermocouples, resistive temperature devices (RTDs Pt100 and thermistors), infrared radiators, bimetallic devices, liquid expansion devices, and change-of-state devices.
Choose the right temperature measurement instrument for your application...

What is a Type K Thermocouple?
A Type K thermocouple refers to any temperature sensor containing Chromel and Alumel conductors, that meets the output requirements as stated in ANSI/ASTM E230 or IEC 60584 for Type K thermocouples. This may be an immersion sensor, a surface sensor, wire or another style of sensor or cable.
Type K wire is primarily available in two color-codes, yellow connectors and/or yellow and red conductors per ANSI/ASTM E230, or green Connector and/or green and white conductors per IEC 60584.

What Are Common Applications for Thermocouples?
Thermocouples are the most widely used temperature sensors on the planet due to their combination of wide temperature capabilities, ruggedness, and low cost. Thermocouples are used in applications that range from home appliances to industrial processes, to electric power generation, to furnace monitoring and control, to food and beverage processing, to automotive sensors, to aircraft engines, to rockets, satellites and spacecraft.
When it comes to high temperatures, small size, fast response, high vibration or shock, most times you will find thermocouples providing the temperature measurements.

eBook / Automotive
OMEGA is an industrial sensor and measurement solutions provider with over 50 years of experience. With the ability to provide a complete range of instruments and engineering services it would be difficult to find a better partner for the automotive industry.
OMEGA has a track record of providing state-of-the-art sensors and measurement instrumentation for the automotive industry. With our vast experience and knowledge in industrial applications and development of high quality measuring instruments, sensors and complete solutions...

Common Techniques to Calibrate Thermocouples
Temperature measurement is possible through several means. We commonly use thermometers for measuring temperature. However, for precision measurements, where even a small spike in temperature requires to be recorded, we use advanced forms of measurement devices like thermocouples. Thermocouples are measurement devices that can read very slight temperature changes. Hence, they are widely used in applications where accuracy is of utmost importance.
However, like any measurement device, the efficiency of thermocouples will deteriorate overtime under constant use. At this point, the thermocouple needs recalibration...
* Fields marked with an asterisk are required
Related products13


Standard Connector with Integral Cable Clamp


Super OMEGACLAD™XL Mineral Insulated Thermocouple Cable


Mini Thermocouple Connector with Cable Clamp


OMEGACLAD™ Mineral Insulated Thermocouple Cable


Standard Connector for Thermocouple, Pt100, Thermistor


High Temperature Ceramic Connector, Standard Size


High Temperature Miniature Ceramic Connector


Miniature Connector for Thermocouple, Pt100, Thermistor


High Temperature Miniature Connector for Vacuum Applications


Low Noise Standard Size Connector


Low Noise Miniature Size Connector


OMEGACLAD™ Mineral Insulated RTD Cable (Pt100)