Flat Surface In Line pH/ORP Electrodes

Specify product selection
Variant does not exist

from € 237.60 excl. VAT
qty
OMEGA Engineering

16 Month Shelf Life. Designed For 3/4", 1", or 2" Pipe Tees. Acryl Gel Standard For High Temperature Applications. CPVC Construction. Maximum Temperature 88°C. More

Item# (PN): PHE-5460_serie Shipping and Payment

The PHE/ORE-5460 in-line pH and ORP electrodes feature a flat self-cleaning abrasion-free surface. When exposed to turbulent flow, the resulting scrubbing action keeps the electrodes clean. The electrodes can be used in applications with 0 to 88°C temperatures, pressures up to 6.89 bar (100 psig) and a 0 to 14 pH measurement range (0 to 12 without sodium ion error). Having fresh material sweeping past the electrode’s surface improves response time as well as accuracy, especially for the measurement of oily waste fluids, lime slurries, flocculant and emulsions. The electrodes accept a cable assembly with a gland mounted in a 3/4", 1" or 2" NPT tee.

In-Line electrodes are ideal for relacing existing threaded electrodes. They are used in applications where flow can be shut off for electrode maintenance.

The high temperature Acrylamide gel is supplied as standard with the PHE-5460 electrodes. These are only available with CPVC construction.

Electrode Options

Ordering Suffix Description Available In Line Models
-HF Fluoride Resistant All pH including PHE-5460-GL
-GL Ground Loop PHE-5460 only (3/4")
-LC Low Conductivity All pH

Complete informations can be found in the spec sheet (PDF), see the "Download" section.