Handheld Hygro Thermometer Data Logger
The RH318 is a high performance handheld meter with data logging ability. It offers a large dual back-lit display to show the temperature and humidity from a handheld probe and can display a dew point measurement. The temperature/humidity probe uses a semiconductor and polymer capacitive sensor and a thermistor temperature sensor.
Windows® based software and USB interface cable is included to allow real time or recorded data to be read by a PC through the USB/RS232 port (RS232 interface cable is optional). Probe can extend up to 1.5 m (5') with optional extension cable.
SPECIFICATIONS:
Sensor Type: Electronic capacitance polymer film sensor/NTC
Relative Humidity Range: 0 to 100% RH
Temperature Range: -20 to 60°C (-4 to 140°F)
Dew Point Temperature Range: -20 to 60°C (-4 to 140°F)
Resolution: 0.1% RH, 0.1°C, 0.1°F
Accuracy Probe (RH318-RP): <10% RH, >90% RH ±4.0% RH 10% RH to 90% RH ±2.0% RH -20 to 60°C (-4 to 140°F) ±0.8°C (±1.5°F)
Response Time (In Slow Moving Air):
Humidity: 180 s
Temperature: 10 s
Sensor Hysteresis: <1.5% RH
Temperature Coefficient: 0.1 x (specified accuracy) per 1°C (<23°C or >23°C)
Sample Rate: Two times per second
Battery Type: 9V battery (included)
Battery Lifetime: Approx. 80 hours (alkaline battery)
AC Adaptor (Optional): 9 Vdc (8 to 10 Vdc max )
Operation Temperature: 0 to 40°C (32 to 104°F)
Operation Humidity: 10 to 90% RH
Storage Temperature: -10 to 60°C (14 to 140°F)
Storage Humidity: 10 to 75% RH
Dimensions
Meter: 185 L × 65 W × 36 mm H (7.3 x 2.6 x 1.4")
Probe: 15 D x 94 mm L (0.6 x 3.7")
Weight: Approx. 285 g (10 oz)
Environment Conditions:
Altitude: Up to 2000 m (6562')
Relative Humidity: 90% max
Operation Ambient Temperature: 0 to 40°C (32 to 104°F)

Why measure relative humidity?
Relative humidity is often overlooked compared to temperature. When a room is too hot or too cold, the response is immediate. Adjust the thermostat, turn on a fan, or add heat. Humidity is different. It is less visible, harder to sense directly, and often addressed only after it causes a problem.
That does not make it less important. Relative humidity plays a measurable role in indoor air quality, process stability, and product integrity across a wide range of applications. Monitoring it allows operators to maintain controlled conditions rather than reacting to issues after they appear.

How is Temperature Measured?
Temperature can be measured via a diverse array of sensors. All of them infer temperature by sensing some change in a physical characteristic. Six types with which the engineer is likely to come into contact are: thermocouples, resistive temperature devices (RTDs Pt100 and thermistors), infrared radiators, bimetallic devices, liquid expansion devices, and change-of-state devices.
Choose the right temperature measurement instrument for your application...

eBook / Automotive
OMEGA is an industrial sensor and measurement solutions provider with over 50 years of experience. With the ability to provide a complete range of instruments and engineering services it would be difficult to find a better partner for the automotive industry.
OMEGA has a track record of providing state-of-the-art sensors and measurement instrumentation for the automotive industry. With our vast experience and knowledge in industrial applications and development of high quality measuring instruments, sensors and complete solutions...