High Temperature Constant Wattage Heating Cable (260°C)
The minimum purchase order quantity for the product is 3 ft = 120 cm. Can be added in 1 ft (30 cm) increments.
The KE Cable heating element is tension wrapped and covered with two layers of nonflammable Polyimide Film applied in reverse directions, then heat fused for moisture protection. A stainless steel and tinned copper sheath is then added for additional protection and electrical ground return path. The sheath is enclosed in a minimum 20 mil PFA abrasion and chemical resistant extruded jacket.
OMEGALUX™ KE Cable is a low Watt density electrical resistance heater. It is designed for freeze protection, viscosity and high temperature process control in Class 1, Groups B, C, and D, Division 2 Classified Areas as well as in corrosive environments. KE is used in asphalt plants, oil refineries, mines, chemical and petrochemical processing areas, other locations where corrosive atmospheres can occur. KE is equally suitable for applications in severe arctic cold.
CAUTION AND WARNING!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.
Max. Circuit Length** KE Series
| Power | 120V | 240V |
| 4 W/ft | 8,8 m | 17,7 m |
| 8 W/ft | 6,2 m | 12,5 m |
| 12 W/ft | 5,1 m | 10,2 m |
** Maximum circuit lengths include end-to-end voltage variation of 10%. Lengths are based on cable operating temperatures of 149°C.
SPECIFICATIONS:
Wattage: 4, 8 and 12 W/ft
Circuit Module Length: 1,2 m for all
Maximum Short Term Exposure Temperature: 287°C (de-energized)
Outside Dimension: Nom. 8.38 x 5.72 mm
Dielectric Strength: In excess of 2500V
Complete informations can be found in the spec sheet (PDF), see the "Download" section.
The online configurator may not contain all available options.
If you do not find what you are looking for, please contact us.