Maximum Temperature Measurement up to 760°C. K and E Thermocouple Calibrations. Straight and Right Angle Probes. Our most popular Models, 88006 and 88007, are ideal for temperature measurement of small electronic parts. All Models supplied with a molded SMP or SMPW subminiature male connector. Standard connector adapters TAS are sold separately. More
Replacement elements for surface probes
High-quality, user-replaceable replacement elements are available for all probes. Replacement elements has been Pre-Aged to assure maximum accuracy. The probe is ready for immediate use after replacement.
Surface temperature probes
Model 88006(*)
Miniature, fast response probe with 480°C max. surface temperature. Ideal for surface temperatures of small electronic parts.
Replaceable Element not supplied, P/N 88006(*)-RE .
Model 88007(*)
Miniature, fast response probe. Ideal for measuring the surface temperature of small electronic parts. 250°C max. surface temperature.
Replaceable Element supplied free, for additional elements order P/N 88007(*)-RE.
Model 88010(*)
Long, 300 mm reach version of the 88006. Fast response design with 760°C max. surface temperature for use in oven and furnaces.
Replaceable Element not supplied, P/N 88010(*)-RE.
Model 88016(*)
High temperature, right-angle probe, with miniature pencil type head. Best suited to stationary surfaces, with sensing head parallel to the handle. 480°C max. surface temperature.
Replaceable Element not supplied, P/N 88016(*)-RE.
Model 88026(*)
High temperature, right-angle probe, with miniature pencil type head. Best suited to stationary surfaces, with sensing head perpendicular to the handle. 480°C max. surface temperature.
Replaceable Element not supplied, P/N 88026(*)-RE.
Model 88106(*)
Right-angle probe for fast response times. Sheath length is 102 mm Max. surface temperature is 760°C.
Replaceable Element not supplied, P/N 88106(*)-RE.
Model 88107(*)
Right-angle, long reach probe with fast response design. Sheath length is 203 mm, with 760°C max. surface temperature.
Replaceable Element not supplied, P/N 88107(*)-RE.
Model 88108(*)
Right-angle, long 300 mm reach probe with fast response design. 760°C max. surface temperature.
Replaceable Element not supplied, P/N 88108(*)-RE.
* Specify Calibration:
K: CHROMEGA™-ALOMEGA™
E: CHROMEGA™-Constantan
Complete informations can be found in the spec sheet (PDF), see the "Download" section.

Thermocouple Sensor / What is a Thermocouple?
A thermocouple is a sensor for measuring temperature. This sensor consists of two dissimilar metal wires, joined at one end, and connected to a thermocouple thermometer or other thermocouple-capable device at the other end. When properly configured, thermocouples can provide temperature measurements over wide range of temperatures.
Thermocouples are known for their versatility as temperature sensors therefore commonly used on a wide range of applications...

How is Temperature Measured?
Temperature can be measured via a diverse array of sensors. All of them infer temperature by sensing some change in a physical characteristic. Six types with which the engineer is likely to come into contact are: thermocouples, resistive temperature devices (RTDs Pt100 and thermistors), infrared radiators, bimetallic devices, liquid expansion devices, and change-of-state devices.
Choose the right temperature measurement instrument for your application...

What is a Type K Thermocouple?

What Are Common Applications for Thermocouples?
Thermocouples are the most widely used temperature sensors on the planet due to their combination of wide temperature capabilities, ruggedness, and low cost. Thermocouples are used in applications that range from home appliances to industrial processes, to electric power generation, to furnace monitoring and control, to food and beverage processing, to automotive sensors, to aircraft engines, to rockets, satellites and spacecraft.
When it comes to high temperatures, small size, fast response, high vibration or shock, most times you will find thermocouples providing the temperature measurements.

eBook / Automotive
OMEGA is an industrial sensor and measurement solutions provider with over 50 years of experience. With the ability to provide a complete range of instruments and engineering services it would be difficult to find a better partner for the automotive industry.
OMEGA has a track record of providing state-of-the-art sensors and measurement instrumentation for the automotive industry. With our vast experience and knowledge in industrial applications and development of high quality measuring instruments, sensors and complete solutions...

Common Techniques to Calibrate Thermocouples
Temperature measurement is possible through several means. We commonly use thermometers for measuring temperature. However, for precision measurements, where even a small spike in temperature requires to be recorded, we use advanced forms of measurement devices like thermocouples. Thermocouples are measurement devices that can read very slight temperature changes. Hence, they are widely used in applications where accuracy is of utmost importance.
However, like any measurement device, the efficiency of thermocouples will deteriorate overtime under constant use. At this point, the thermocouple needs recalibration...
* Fields marked with an asterisk are required