Pressure Smart Probe
Omega Link Pressure Monitoring Smart Probes. Software configurable through SYNC configuration software. Modular M12 construction. OMEGA Smart Core enabled. All Stainless steel body. Battery powered long range wireless capable with IF-006-Series. 10,000+ sample data/event logging. More
Item# (PN): SP-006-1 Shipping and Payment
Omega Link Pressure Monitoring Smart Probes measure gas, liquid, and vapor pressure for a wide range of applications. Featuring all stainless-steel pressure sensor construction and available in 1, 50, 100, and 250 psi configurations. No excitation is required as power is provided by Omega Link modular wireless or wired interfaces via a rugged M12 connector.
Users may apply a calibration correction to the measured pressure using either 1 single offset or a calculated 2-point correction for improved accuracy across the entire measurement range.
Temperature data is also available for monitoring the internal temperature of the pressure sensor.
Intuitive Configuration
Configure your Omega Link Smart Probe using our free SYNC configuration software. Configurable features include selective data extraction, measurement and device traceability, local alarms, and adaptive transmission rates.
Edge Control and Built in I/O
The Omega Link SP-006 features 2 discrete I/O pins. These can be used for a myriad of applications including driving relays, physical alarms, or sensing dry contacts like door switches. The SP-006 can also be utilized as an edge controller, with autonomous independent decision-making capabilities to generate local alarms or provide control outputs based on sensor inputs.
Smart Core Enabled
Smart Core is integral to all Omega Link Smart Sensing Devices. In addition to allowing for modular integration to the Omega Link Ecosystem using any Omega Link Smart Interface, this powerful suite of advanced features enable plug-and-play connectivity, alarm and notifications, data logging, SYNC configuration, and storage of 10,000 data points and events.
Smart Interface Modularity
Customize your Omega Link Ecosystem by taking advantage of discrete I/O features accessible through the modular addition of an M12.8-T-SPLIT and M12.8-S-M-FM terminal.
Long-Range Wireless Solution*
Pairing the SP-006 with the IF-006 Series interface produces a self-contained, long-range, wireless solution. This setup can also be externally powered by adding the UNIV-AC100/240-M8 power adaptor.
*Note: IF-006 must be paired with an Omega Link wireless gateway
Your Data at a Glance with Omega Link Cloud
Omega Link Cloud consolidates and brings your data to you when you need it, wherever you are. The intuitive cloud interface allows you to monitor and store your data, set alarms and alerts, and provides insights on device activity.
SPECIFICATIONS:
PRESSURE
Range: 1, 50, 100, 250 PSI
Accuracy: ±0.5% full-scale
Resolution: 0.1
Absolute Maximum Pressure: 1.5 times full-scale for each range (Caution: Do not exceed 500 psi)
INTERNAL SENSOR TEMPERATURE
Range: -10 to 800 °C
Accuracy: ±1.50 °C
Resolution: 0.10 °C
INPUT POWER
Voltage: 2.8 Vdc - 3.3 Vdc
DIO DIGITAL INPUTS
VinHighThreshold = 2.2 Vmax
VinLow Threshold = 0.3 Vmin
VinMAX = 30 Vdc
DIO DIGITAL OUTPUTS
2x Open Drain 200 mA max
VMAX = 30 Vdc
ENVIRONMENTAL
Storage Temperature: -40 to 850 °C; less than 95% RH, non-condensing
Environmental Rating: IP50
GENERAL
Configuration: Configurable with a Omega Link Smart Interface such as the IF-001 USB Adaptor and SYNC configuration software.
Smart Interface Connectivity: USB (IF-001), Modbus (IF-002), Wireless (IF-006).
Software: Compatible with OEG (Omega Enterprise Gateway) and SYNC configuration software.
Upgrade Legacy Systems to IIoT and Achieve More
Industrial Internet of Things or IIoT is a prerequisite for industries looking to embrace digital transformation. It is through this connected ecosystem that businesses gain increased visibility in their processes, ensure equipment uptime, perform predictive maintenance, and increase productivity and profitability.