Process and Thermocouple Calibrator

Special Offer -30% Discount On Stock
Original price € 687.70 excl. VAT. Save 30% (€ 206.30 excl. VAT) € 481.40 excl. VAT
can be ordered - date of dispatch to be specified
qty
OMEGA

Current Calibrator 0/4 to 22 mA, Source/Sink. Voltage Calibrator 0 to 14 V, mV Ranges 0 to 28 mV and 0 to 560 mV. Thermocouples type J, K, N, R, S, T, B, E. Multimeter ±2 Vdc to ±200 Vdc and ±100 mA. Simultaneous Calibration and Measurement. Steps, Ramps, direct entry. Built-in rechargeable Battery. More

Item# (PN): OC502-t Shipping and Payment

OC502-t is a Calibrator-Multimeter for generation of currents 0/4 to 22mA in Source or Sink Mode and voltages 0 to 14V. External voltages ±2V, ±20V and ±200VDC and currents of up to ±100mA can be measured simultaneously.  

Two mV-Ranges 0-28mV and 0-560mV are available for calibration of Strain Gauges circuits, low signal amplifiers, Transmitter signal circuits and other mV-Applications.

DIN Thermocouples J, K, N, R, S, T, B, E can be simulated. The required sensor type will be selected and the temperature value set with the keyboard. The temperature value is shown on the display and the corresponding mV signal is available at the output terminals. Internal cold junction compensates the termination against the ambient temperature. The compensation can be switched off.

The calibrator operates from an internal rechargeable Li-Ion battery which permits 9 hours of operation with 20mA output current. All measuring ranges can be calibrated individually by using the internal calibration software. The calibrator is shipped with battery charger, two cables, calibration sheet and owner's manual. 

Functions:

  • Tare, Filter and Backlight can be selected.
  • Direct selection of the output signal value with the keyboard.
    The current can be set from 0 to 22.000 mA, the voltage from 0 to 14.000 V.
  • Rising or falling ramps 0-14 V or 0-22 mA with selectable increments.
  • Selection of mV Signals 0-30 mV or 0-600 mV with resolution of 0.001 mV or 0.01 mV.
  • mV Signals of DIN - Thermocouples J, K, N, R, S, T, B, E with or without cold junction compensation.
  • Preselected signal steps 0-2-4-6-8-10-12-14V and 4-8-12-16-20 mA

SPECIFICATIONS:

CALIBRATOR

Accuracy: ± 0.05% from value + 0.1% from range
Process ranges:
DC A 0/4 - 22 mA DC Source or Sink, Resolution 0.001mA
DC V 0 - 14 V DC Resolution 0.001V
mV Output 0-28 mV DC Resolution 0.001mV
0-560mV DC Resolution 0.01mV

Thermometer: Thermocouples J, K, N, R, S, T, B, E according to ITS-90
The Terminals are internally compensated to the ambient temperature

Signal Output:
Direct Setting - With the keyboard, 5 digits resolution
In Steps - 4/8/12/16/20/22 mA and 0/2/4/6/8/10/12/14 V
Ramps: Rising, falling or automatic ramps with selectable increments

MULTIMETER

Accuracy: ± (0.1% from range + 1 Digit)
Ranges:
2 V DC Input Impedance: 1.38 M Ohm
20 V DC Input Impedance: 593 k Ohm
200 V DC Input Impedance: 563 k Ohm
100 mA DC Input Impedance: 10 Ohm

Complete specifications can be found in the spec sheet (PDF), see the "Download" section.